ELI.H.A Echinococcus

Indirect hemagglutination test for serodiagnosis of Hydatidosis.

ELI.H.A Echinococcus enables the quantitative determination, by indirect hemagglutination, of serum antibodies present in patients suffering from hydatidosis (Echinococcus granulosus).

  • Liquid ready-to-use reagents
  • Cost-effective test
  • High sensitivity and specificity
  • Fast results for clinicians (2 hours)
  • Simple visual reading, without expert interpretation

 

Reference Name Quantity
66604 ELI.H.A Echinococcus 102

 

ELI.H.A Echinococcus hydatidose quantitative detection

Benefits

Intended Use

Hydatidosis or echinococcosis is a parasitic disease caused by the larvae (hydatids) of a cestode of theEchinococcus genus. The life-cycle of Echinococcus granulosus requires both definitive and intermediate hosts. In general, the dog is the definitive host, with sheep and in rare cases humans being the intermediate host. The hydatids are most frequently found in the liver (50 to 70%) and then the lungs (25 to 40%). E. granulosushydatid infection is characterized by a slow and insidious disease progression. Infection is relatively asymptomatic, with biological diagnosis resting primarily upon the detection of antibodies. ELITech developed the ELI.H.A Echinococcus, an indirect hemagglutination assay, for the quantitative determination of anti-Echinococcus granulosus antibodies in the serum. It is rapid, easy-to-use and easy-to-read with results available within 2 hours and reliable overnight.


Principle

Sheep red blood cells are sensitized with Echinococcus granulosusantigen. Diluted serum is mixed with sensitized sheep red blood cells. If anti-Echinococcus granulosus antibodies are present in the serum, sensitized red blood cells will agglutinate, resulting in a cloudy red/brown deposit coating the well. In the absence of specific antibodies, sensitized red blood cells will not agglutinate, resulting in a ring-like deposit at the bottom of the well. Non-sensitized red blood cells are also available in the kit. They ensure the specificity of the reaction by allowing identifying any interference from the natural anti-sheep agglutinins (Forssman heteroantibodies, infectious mononucleosis antibodies…). The reaction is carried out in a U-microplate. Each kit allows 102 tests to be carried out or 17 reactions of 6 dilutions. Results are obtained within 2 hours and are reliable overnight.


Simple Protocol

A single protocol for all our ELI.H.A kits.

  1. First serum dilution
  2. Micrplate preparation
  3. Serial dilution of serum and preparation of the ‘serum control’ well
  4. Addition of sensitized RBC and non sensitized RBC
  5. Gently mix the plate and let stand 2 hours before readingo

eliha_methodology[1]

The following procedures are therefore valid for all our ELI.H.A range:


Easy-to-Read and Easy-to-Interpret Result

eliha_results[2]

Titer Interpretation
< 1:80 Non-significant reaction
Probable absence of hydatidosis infectionRenew the test 2 to 3 weeks later and also carry out an electrosyneresis or an immunoelectrophoresis test
1:80 ≤ T ≤ 1:160 Doubtful reaction
Renew the test 2 to 3 weeks later and also carry out an electrosyneresis or an immunoelectrophoresis test
≥ 1:320 Significant reaction in favor of progressive hydatidosis

 

Reagents and Material

Quantity Description
1 R1: Vial of 2.2 mL of sensitized red blood cells
1 R2: Vial of 1mL of non-sensitized red blood cells
1 BUF: Vial of 55 mL of phosphate buffer pH 7.2
1 R3: Vial of 2 mL of adsorbent
1 CONTROL +: Vial of 0.2 mL of titrated positive control
1 CONTROL : Vial of 0.2 mL of negative control
2 MICROPLATE: Microplate with a U-bottom
2 DROPPER: Special dropper

Material Required but Not Supplied

  • Automatic pipette(s) with a pipetting volume adapted to the volume that will be measured
  • Contaminated waste containers
  • Centrifuge
  • Hemolysis tubes

Stability and Storage

  • The reagents are liquid and ready-to-use.
  • All the reagents are stored at 2-8°C. Do not freeze.
  • The results of the stability study indicate that the product has a stability of 24 months at 2-8°C from its manufacture.

Performances

Sensitivity Specificity
93% 94.9%

 

Manufacturer: ELITech Microbio.
Product(s) intended for healthcare professionals.
Read the instructions on the label and/or instructions for use of the product(s).

Gants de protections et normes : mode d'emploi - Blog Gants Medicaux

Let us help you

For general inquiries, please use the links to the right. Click Contact to complete a brief online form, or click Support for general phone and email information. Someone will be in touch with you soon.