ELITex Staph
Latex slide agglutination test for the rapid identification of Staphylococcus aureus.
ELITex Staph is a slide agglutination test for the rapid identification of Staphylococcus aureus (MRSA included) from primary culture plates.
- MRSA and MSSA identification
- Cost-effective routine laboratory test
- Easy and ready-to-use
- High sensitivity and specificity
- Fast results for clinicians (<1min)
- Simple visual reading, without expert interpretation
The ELITex Staph assay is important in the management of patients with septicemia and nosocomial infections.
Reference | Name | Quantity |
22711 / 22712 | ELITex Staph | 60 / 160 tests |
Image Gallery
Benefits
Intended use
Staphylococci are a serious problem for hospital epidemiology. Among them, Staphylococcus aureus is the main pathogenic species and is responsible for septicemia and nosocomial infections. Multi-drug resistance poses considerable therapeutic problems, particularly with respect to methicillin resistant staphylococci. The ability to rapidly differentiate Staphylococcus aureus from other staphylococci species is therefore a necessity in microbiological diagnosis. The ELITex Staph is a slide agglutination test for the rapid identification of Staphylococcus aureus (MRSA included) from primary culture plates. It is rapid, easy-to-use and easy-to-read with results available within 1 minute.
Principle
Red latex particles are sensitized with three proteins:
- Fibrinogen that reacts with “Clumping Factor”.
- The Fc fragment of human IgG that reacts with Staphylococcus aureus protein A.
- Anti-Staphylococcus aureus capsular polysaccharides polyclonal IgG.
The presence of Staphylococcus aureus is revealed by a strong agglutination reaction. In the absence of Staphylococcus aureus, no agglutination appears. The test procedure is easy with results available in less than a minute. The kit is complete and includes:
- TEST LATEX
- CONTROL LATEX (internal control)
- Test cards
- Single use sticks
Simple protocol
Easy-to-read and easy-to-interpret results
TEST LATEX | CONTROL LATEX | Interpretation |
– | – |
Negative reaction The strain tested is not Staphylococcus aureus |
– | + | |
+ | – |
Positive reaction The strain tested is Staphylococcus aureus |
+ | + | Uninterpreted reaction |
Reagents and material
Reference | Quantity | Description |
22711 | 1 | TEST LATEX: Dispenser vial of 1.8 mL of sensitized latex |
1 | CONTROL LATEX: Dispenser vial of 1.8 mL of unsensitized latex | |
15 | TEST CARD: Disposable reaction card | |
120 | STICK: Disposable mixing sticks |
Reference | Quantity | Description |
22712 | 2 | TEST LATEX: Dispenser vial of 2.4 mL of sensitized latex |
2 | CONTROL LATEX: Dispenser vial of 2.4 mL of unsensitized latex | |
40 | TEST CARD: Disposable reaction card | |
320 | STICK: Disposable mixing sticks |
Stability and storage
- The reagents are ready-to-use.
- All the reagents are stored at 2-8°C. Do not freeze.
- The results of the stability study indicate that the product has a tability of 18 months at 2-8°C from its manufacture.
Performance
- ELITex Staph assay has a good sensitivity for methicillin resistant strains of Staphylococcus aureus (MRSA), producing little protein A and/or fibrinogen affinity factor. The sensitivity of the assay is 99.02% and its specificity is 99.07%.
Material required but not supplied
- Incubator calibrated at 37°C
- Contaminated waste container
Manufacturer: ELITech Microbio.
Product(s) intended for healthcare professionals.
Read the instructions on the label and/or instructions for use of the product(s).