Aerospray® Hematology Pro Series 2

Market Segment: ,

Unsurpassed alcohol based stain quality staining with user flexibility and convenience.

“Delivering textbook quality staining with trouble-free operation.”

The new Series 2 stainers fulfills Today’s needs for Laboratories, with an easy and intuitive 21st century interface.

The Aerospray Hematology Pro automated slide stainer is a necessity to any hematology laboratory because it can be adjusted to a wide range of staining requirements. The run time is short with slides ready for the microscope in five minutes giving superior results. Only fresh alchohol based reagent is applied as an atomized spray on slides mounted in a rotating carousel. Specimens contact only fresh stain, precisely metered from separate spray nozzles. Accuracy is assured.
With the addition of the optional Cytopro® Cytocentrifuge Rotor, the Hematology Pro is also able to deposit cells onto microscope slides.

Catalogue Number(s)

Model 7152
Product Description: Aerospray® Pro Series 2 Slide Stainer/Cytocentrifuge

AC-160
Product Description: Optional Cytopro® Rotor

Downloads

Aerospray® Hematology Pro Series 2

Aerospray® Hematology Pro Series 2

The Aerospray Hematology Pro Series 2 automated slide stainer is a dual-purpose microprocessor-controlled slide staining and cell preparation system.


The Aerospray Process for Hematology Staining

The Aerospray Hematology Pro Slide Stainer/Cytocentrifuge combines ELITech’s advanced staining technology with the advantage of alcohol based staining routines plus powerful custom staining options. With its rapid staining cycle and high throughput capability, the Aerospray Stainer is a convenient, cost-effective way to stain Hematology specimens.

hemato_pro_chart_s[1]


Aerospray technology: reagents applied from atomizing spray nozzles

Aerospray technology: reagents applied from atomizing spray nozzles

HOW IT WORKS:

Reagents are applied from atomizing spray nozzles onto the slides. Staining is rapid and precise. Only fresh stain contacts specimens avoiding cross-contamination or contact with used reagents. Fixation can be done in the instrument or slides can be hand fixed.

With the addition of the Cytopro rotor, body fluids can be processed in the stainer, making it a dual purpose instrument in one convenient footprint.

DETAILS MAKE THE DIFFERENCE:

Example of Hematology staining with the Aerospray system

Example of Hematology staining with the Aerospray system

Simultaneous contact by both dyes produces the classic staining patterns withsuperior, textbook quality results. The thiazin and eosin dyes are loaded separately onto the instrument to correct the reagent stability problems common to mixed stains. These stains are automatically combined and mixed prior to application to produce superior results.In fact, many customers purchase the Aerospray Pro just for its superior staining of bone marrow smears.

SUPERIOR STAINING FLEXIBILITY:

Aerospray offers a versatile selection of 9 different intensities for each of the 4 set programs: Rapid Wright-Giemsa, Wright-Giemsa, May-Grünwald Giemsa, and Custom Stain with simple adjustment routines to tailor the staining to individual preferences.

A programmable function is also available for special staining Requirements.


Dual-purpose Instrument

Rotor Carousel

With the optional Cytopro®rotor, the Aerospray Stainer becomes a superb cytocentrifuge with eight-slide capacity and programmability, at a fraction of the cost of purchasing a stand-alone cytocentrifuge.


Everything under control

Would you like to secure your settings with an administrator password? Do you want to be reminded to perform preventative maintenance or stain a QC slide? Just program the stainer as you like and the system will remind you. And don’t worry about reagents and waste – the stainer alerts you to expired shelf life, or critical reagent or waste levels.


More traceability

Scan SlideNeed to reinforce your QC management and ensure compliance with new lab requirements? The Hematology PRO series 2 memory stores critical information including: reagent data, specimen ID, user ID, and cycle operation history–all exportable via a USB port. The new barcode scanner streamlines data entry, while manual keyboard entry is still an option.


Economical

The Aerospray Hematology Pro Stainer is exceptionally sparing when it comes to reagent consumption. Programmability significantly reduces the volume of reagents required for staining partial loads and thereby significantly lowers reagent cost.


Rapid performance

With a cycle time as short as 5minutes, the Aerospray Stainer can process more than 115 slides per hour (up to 288 with the optional 30-slide carousel). No more waiting for slides to dry–they’re ready to view when the staining cycle ends.


Easy to use

screen-stain_programs[1]Simply select the user-defined program and start the stain cycle. The stainer takes over from there, precisely controlling all phases of the stain cycle with virtually perfect reproducibility. Automated nozzle clean and purge after each stain cycle ensures performance without user intervention.

barcode bottleEnjoy a friendly user interface with many innovative features at your disposal, such as large touch screen, language selection, help screens, nameable and recordable programs, and easy updates with the USB serial port.

Slide Carousel Capacity

  • 1 to 12 or 1 to 30 Slides, depending on carousel

Cytocentrifuge Rotor Speed

  • 100-2000 rpm (± 5%), user programmable

Dimensions (W x H x D)

  • 57 cm x 25 cm x 54 cm (22” x 10” x 21”)

Clearance Height (lid open)

  • 58 cm (23”).

Weight

  • 15.2 kg (33.5 lb).

Electrical Requirements

  • 100 to 240 VAC (±10%), @ 50-60 Hz, 200 watts maximum

Drain Connection

  • Outlet on rear panel.

Safety

  • Lid interlock: Lid must be closed for operation, and is locked down during carousel rotation.

Reagent Level Detect

  • Level detection on all reagent lines

Waste Level Detect

  • Level detection in waste bottle

SDS List

SDS-00018: REV A SDS, USA Version for SS-MeOH

SDS-00018-DE: REV A SDS, German Version for SS-MeOH

SDS-00018-EN: REV A SDS, EU Version for SS-MeOH

SDS-00018-ES: REV A SDS, Spanish Version for SS-MeOH

SDS-00018-FR: REV A SDS, French Version for SS-MeOH

SDS-00018-IT: REV A SDS, Italian Version for SS-MeOH

SDS-00018-PT: REV A SDS, Portuguese Version for SS-MeOH

SDS-00019: REV A SDS, USA Version for SS-071A, Diluted SS-171A, SS-171A-EU

SDS-00019-EN: REV A SDS, EU Version for SS-071A, Diluted SS-171A, SS-171A-EU

SDS-00020: REV A SDS, USA Version for SS-072A, Diluted SS-172A, SS-072A-EU

SDS-00033: REV A SDS, USA Version for SS-029, Diluted SS-029C, SS-029C-EU

SDS-00033-DE: REV A SDS, German Version for SS-029, SS-029C

SDS-00033-EN: REV A SDS, EU Version for SS-029, Diluted SS-029C, SS-029C-EU

SDS-00033-ES: REV A SDS, Spanish Version for SS-029, SS-029C

SDS-00033-FR: REV A SDS, French Version for SS-029, SS-029C

SDS-00033-IT: REV A SDS, Italian Version for SS-029, SS-029C

SDS-00033-PT: REV A SDS, Portuguese Version for SS-029, SS-029C

SDS-00034: REV B SDS, USA Version for SS-029C, SS-029C- EU

SDS-00034-DE: REV B SDS, German Version for SS-029C, SS-029C- EU

SDS-00034-EN: REV C SDS, EU Version for SS-029C, SS-029C- EU

SDS-00034-ES: REV B SDS, Spanish Version for SS-029C, SS-029C- EU

SDS-00034-FR: REV C SDS, French Version for SS-029C, SS-029C- EU

SDS-00034-IT: REV B SDS, Italian Version for SS-029C, SS-029C- EU

SDS-00034-PT: REV A SDS, Portuguese Version for SS-029C, SS-029C- EU

SDS-00050: REV A SDS, USA Version for SS-049A, SS049A-EU

SDS-00050-EN: REV A SDS, EU Version for SS-049A, SS049A-EU

SDS-00051: REV A SDS, USA Version for SS-049C, SS049C-EU

SDS-00051-EN: REV A SDS, EU Version for SS-049C, SS049C-EU

SDS-00052: REV A SDS, USA Version for SS-049P and SS-049P-EU